Pet Cremation Incinerator for Veterinary Clinics & Pet Funeral Homes (30–50 kg/h TS50PET)

Pet Cremation Incinerator for Veterinary Clinics & Pet Funeral Homes (30–50 kg/h TS50PET)

Pet Cremation Incinerator System (30–50 kg/h)

Product Overview

The HICLOVER TS50PET Pet Cremation Incinerator is a dedicated, industrial-grade cremation solution developed specifically for the dignified, safe, and environmentally responsible disposal of animal remains. Built on time-tested dual-chamber high-temperature incineration technology and supported by enhanced flue-gas management stages, the TS50PET delivers stable combustion performance, low ash residue, reduced odor, and highly dependable day-to-day operation.

This system is ideal for veterinary clinics, animal hospitals, municipal animal care facilities, and professional pet cremation service providers seeking consistent cremation quality while meeting modern expectations for clean operation and operator safety.

To suit different site conditions and local energy availability, the TS50PET supports diesel (standard), natural gas, or LPG, and it can be upgraded with optional wet flue-gas treatment and mobile deployment formats (containerized or trailer-mounted). This flexibility enables smooth integration into both permanent sites and rapidly deployed cremation service points.

HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]


Waste Type & Treatment Method

  • Waste Type: Pet cremation (animal remains)

  • Treatment Method: High-temperature incineration

  • Target Capacity: 30–50 kg/hour

  • Feeding Mode: Manual batch feeding


System Configuration

The TS50PET adopts a multi-stage combustion and flue-gas control architecture to ensure thorough oxidation and controlled emissions:

1) Primary Combustion Chamber

The main cremation chamber performs direct incineration of animal remains under controlled high temperature for stable and complete burnout.

2) Particulate Sedimentation & Flue-Gas Retention Chamber

A reinforced conditioning chamber designed for particulate settling and extended flue-gas residence time, improving combustion completeness and supporting cleaner exhaust management.

3) Mix Combustion Chamber

A high-temperature mixing zone that stabilizes gas flow, strengthens oxidation efficiency, and prepares flue gas for the next high-temperature stage.

4) Secondary Combustion Chamber

A dedicated high-temperature chamber for deep oxidation of flue gases from the primary chamber, supporting effective removal of odor and organic compounds, and ensuring high destruction efficiency.

5) Chimney System

A 6-meter SS304 stainless-steel stack provides stable draft and safe discharge.

6) Control System

A PLC-based automation package manages operating logic and safety interlocks, with integrated alarms and protection functions to reduce operator workload and improve reliability.


Typical HICLOVER System Highlights

  • Proven dual-chamber combustion with extended gas residence time (≥ 2.0 seconds)

  • Adjustable high-temperature retention (HTR) logic for stable cremation results

  • Italy-brand burners with automatic ON/OFF operation

  • Intelligent fuel-saving strategy with temperature-linked burner control

  • APO (Automatic Protection Operator) safety concept for secure operation

  • Dry scrubber included as standard, optional wet scrubber system available

  • Modular structure supporting fixed installation or mobile deployment

  • Heavy-duty refractory build for long operating life

  • Simple controls, low maintenance requirements, strong reliability for daily use


Pet Cremation–Dedicated Engineering

Unlike general waste incinerators, TS50PET is optimized around the practical needs of modern pet cremation services:

  • Chamber sizing matched to common animal body ranges for better heat utilization

  • Stable flame control and precise temperature regulation for respectful, complete cremation

  • Low ash residue (≤ 5%), easier handling, and movable waste/ash bed design

  • Odor-controlled performance supported by secondary combustion and optional wet scrubbing

  • Compact, quiet, and clean-running layout suitable for clinics and urban environments


Key Technical Data (HICLOVER TS50PET)

Capacity & Operation

  • Design Capacity: 30–50 kg/h

  • Feed Capacity: 50–80 kg per feeding

  • Gas Residence Time: ≥ 2.0 seconds

Combustion Chambers

  • Primary Chamber Volume: 560 L

  • Particulate Sedimentation & Gas Retention Chamber: 180 L

  • Mix Combustion Chamber: 50 L

  • Secondary Chamber Volume: 280 L

Temperature Range

  • Primary Chamber: 800–1000 °C

  • Secondary Chamber: 1000–1300 °C

Fuel & Consumption

  • Fuel Options: Diesel / Natural Gas / LPG

  • Diesel Consumption (Theoretical): ~14 kg/h

  • Natural Gas Consumption: ~16 m³n/h

Burner Configuration

  • Primary Chamber: G10LC single-stage burner ×1 (8 kg/h)

  • Secondary Chamber: G10LC single-stage burner ×1 (8 kg/h)

Electrical System

  • Voltage: 220 / 380 V

  • Power: 0.7 / 3.0 kW

Control & Safety

  • PLC automatic control

  • Continuous feeding protection sensors

  • Temperature monitoring via corundum probe tube (1600 °C rated)

  • Automatic cooling, alarms (display / voice / light), and testing mode

Structure & Materials

  • Hot Face Refractory: ≥115 mm, 65% Al₂O₃, 1750 °C grade

  • Cold Face Insulation: High-grade refractory ceramic fiber

  • Chimney: SS304, 6 m height

  • External Paint: 250 °C heat-resistant coating

Dimensions & Weight

  • External Dimensions: 190 × 130 × 155 cm

  • Gross Weight: 5,000–7,000 kg


Flue Gas Treatment Options

Standard (Included)

  • Dry Scrubber System

Optional Wet Scrubber Package

  • First-stage SS spray tower (primary scrubber)

  • Second-stage SS spray tower (secondary scrubber)

  • SS demister tower

  • SS demisting & dust-removal filter

  • Integrated water tank + induced draft (ID) fan


Optional Configurations

  • Containerized mobile type

  • Trailer-mounted or sledge-mounted mobile versions

  • Dual-fuel system (oil & gas)

  • Flame observation window

  • Fire grate

  • Heat Recovery Technology (HHT)


Compliance & Manufacturing

  • CE compliance: 2006/42/EC, 2014/30/EU

  • ISO 9001:2015 certified manufacturing

  • No asbestos or mercury-containing materials

  • High-tech enterprise certification


Summary

HICLOVER TS50PET combines proven, traditional dual-chamber cremation fundamentals with a forward-looking modular and upgradeable system design, delivering a stable, clean, and respectful cremation solution tailored for modern pet care and professional cremation operations.

  1. Pet Cremation Incinerator for Veterinary Clinics & Pet Funeral Homes (30–50 kg/h TS50PET)

  2. High-Temperature Dual-Chamber Pet Cremation Machine with Low Odor and Low Ash Residue

  3. Eco-Friendly Pet Cremation Incinerator System for Urban Animal Hospitals and Cremation Centers

  4. CE-Compliant Pet Cremation Incinerator with Dry Scrubber and Optional Wet Scrubber (TS50PET)

  5. Professional Pet Cremation Equipment for Animal Remains Disposal: Reliable, Clean, and Respectful Solution

Mobile: +86-13813931455(WhatsApp)

Email:     [email protected]     
Email:     [email protected] 

 

2026-01-17/21:10:06

[ecwid widgets="productbrowser search categories" default_category_id="CATEGORY_ID" default_product_id="PRODUCT_ID" lang="EN"]

Related Posts

Advanced HICLOVER Waste Incinerators: Integrating Engineering Precision with Economic Efficiency

Advanced HICLOVER Waste Incinerators: Integrating Engineering Precision with Economic Efficiency The adoption of advanced Somalia pet incinerator systems, which comply with high industrial standards and specific temperature…

HICLOVER Waste Incinerators: Cost-Effective Solutions for Global Waste Management

HICLOVER Waste Incinerators: Cost-Effective Solutions for Global Waste Management Informational Layer: Understanding Waste Incineration Waste incineration is a waste treatment process that involves the combustion of organic…

HICLOVER Waste Incinerators: Engineering Reliability and Global Market Leadership in Waste Management

HICLOVER Waste Incinerators: Engineering Reliability and Global Market Leadership in Waste Management 1. What are waste incinerators and how do they work? Waste incinerators are specialized incineration…

steps of medical waste management

Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed…

animal incinerator prices

animal incinerator prices according to the capacity or the size want to cremation. The pet cremation equipment humanized design with movable platform, small space covers for modern…

Pyrolytic Double Chamber Incinerator Small Size:Burning Rate:30-45 kg/hr;Maximum Load Capacity:400 kg

Items/Model TS50(PLC) Picture Principle Solid Waste Incineration Burn Rate 30-45 kg/hour Control Mode PLC(Programmable Logic Controller Incinerator) Combustion Chamber 560L Internal Dimensions 100x80x70cm Secondary Chamber 280L Smoke…