Incineration is also called as combustion. … Important use of incineration is that it reduces volume of
waste by 20-30% of original volume. This process is also known as thermal treatment where solid waste materials are
converted by Incinerators into heat, gas, steam and ash.
Do all hospitals have incinerators?
Two common methods of disposing of hospital-generated medical waste include incineration or autoclaving. Incineration is a process that burns medical
waste in a controlled environment. Some hospitals have on-site incineration technology and equipment available.
How do hospitals dispose of placentas?
Hospitals treat placentas as medical waste or biohazard material. The newborn placenta is placed in a
biohazard bag for storage. … Once the hospital is done with the placenta, it is put on a truck with all the
other medical waste accumulated at the hospital for proper disposal
HICLOVER is growing brand for environmental protection field, and market share with most of Africa, Middle East, Southeast Asia countries and part of North America, Europe territory. We are trusted partner for governmental organizations, non-profit organizations, international contractors, logistics organizations, military, pet cremation business owners, etc. We have export experience more than 40 countries, including war zone like Iraq, Afghanistan, Somalia, South Sudan. Mobile: +86-13813931455(WhatsApp) Website: www.hiclover.com Email: [email protected] Email: [email protected]
incineration of sewage sludge
possible solution to get rid of medical waste in oman
irradiation of medical waste
incinerator repair and service
household waste incinerators in india
explanation on incineration in health centre
ensnertor technician
Nanjing Clover Medical Technology Co.,Ltd.
Items/Model
TS10(PLC)
TS20(PLC)
TS30(PLC)
TS50(PLC)
Burn Rate (Average)
10-20 kg/hour
20-30 kg/hour
30-50 kg/hour
50-100 kg/hour
Control Mode
PLC Auto.
PLC Auto.
PLC Auto.
PLC Auto.
Combustion Chamber
100L
210L
330L
560L
Internal Dimensions
50x50x40cm
65x65x50cm
75x75x60cm
100x80x70cm
Secondary Chamber
50L
110L
180L
280L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Power
0.75Kw
0.83Kw
0.99Kw
1.2Kw
Diesel Oil Consumption (kg/hour)
Ave.8.4
Ave.10.9
Ave.13.3
Ave.16.9
Natural Gas Consumption (m3n/hour)
Ave.10.1
Ave.13
Ave.16
Ave.20.2
Temperature Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
Items/Model
TS100(PLC)
TS150(PLC)
TS300(PLC)
TS500(PLC)
Burn Rate (Average)
100-150 kg/hour
150-200 kg/hour
300-400 kg/hour
500-600 kg/hour
Control Mode
PLC Auto.
PLC Auto.
PLC Auto.
PLC Auto.
Combustion Chamber
1200L
1500L
2000L
3000L
Internal Dimensions
120x100x100cm
150x100x100cm
170x120x100cm
210x120x120cm
Secondary Chamber
600L
750L
1000L
1500L
Smoke Filter Chamber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Dry Scrubber
Feed Mode
Manual
Manual
Manual
Manual
Voltage
220V
220V
220V
220V
Power
1.38Kw
1.69Kw
2.57Kw
4.88Kw
Diesel Oil Consumption (kg/hour)
Ave.20.4
Ave.24.2
Ave.33
Ave.44
Natural Gas Consumption (m3n/hour)
Ave.24.5
Ave.29
Ave.39.6
Ave.52.8
Temperature Monitor
Yes
Yes
Yes
Yes
Temperature Protection
Yes
Yes
Yes
Yes
The Contractor shall deploy an expert incinerator operator, fully equipped with all required tools and equipment, to support the client in un-packing, installation, and commissioning of the different sizes of incinerator units.
The operator will be provided on a day-rate reimbursable basis. The bidder must specify the minimum scope of work in terms of operator working days and travel days.
Rates for these to be provided on the financial offer form.
All associated fittings and connections to enable full functionality shall be completed by the bidder in line with the manufacturer’s
instructions; including but not limited to piping, electrical and stack connections, foundations, anchorage to foundations, etc., as applicable
“Handover of the unit
The Contractor shall hand over ownership and control of each size of unit to the client after the first 5 days of supervised operation.
The handover process shall include a detailed inspection and completion of a checklist and statement of operability.
”
“Decommissioning, overhaul and repacking of the unit
Based upon a potential need for an incinerator unit to be moved to a new location the contractor will outline the key steps through a
clear written procedure and direct demonstration by the contracted operator for the decommissioning and repacking of the units, so this can be achieved.
HICLOVER Solution for Fighting COVID-19, with ISO9001/CE Certification.
Medical Waste Incinerator & Auto Roll Air Filter(Air Purification)
Advanced HICLOVER Waste Incinerators: Integrating Engineering Precision with Economic Efficiency The adoption of advanced Somalia pet incinerator systems, which comply with high industrial standards and specific temperature…
HICLOVER Waste Incinerators: Cost-Effective Solutions for Global Waste Management Informational Layer: Understanding Waste Incineration Waste incineration is a waste treatment process that involves the combustion of organic…
HICLOVER Waste Incinerators: Engineering Reliability and Global Market Leadership in Waste Management 1. What are waste incinerators and how do they work? Waste incinerators are specialized incineration…
Average 20%-25% of the total waste generated by healthcare establishments is regarded as hazardous and may create a variety of health and environmental risks if not managed…
animal incinerator prices according to the capacity or the size want to cremation. The pet cremation equipment humanized design with movable platform, small space covers for modern…